Vendor/Supplier Manufacturer Reagent # * Size Inventory Date Cas Number Chemical Formula Room Location Product Code Hazard Category
AK Scientific AK Scientific 1-(2,6-Dochlorophenyl)-2-indolinone 1 * 100 g 15362-40-0 C14H9C12NO H211 Fridge - Health Hazard J91414 Warning - Irritant
AK Scientific AK Scientific Methyl oxindole-6-carboxylate, 97% Add to Favorites 1 * 25 g 14192-26-8 C10H9NO3 H211 Fridge - Health Hazard J91155 Warning - Irritant
Sigma Aldrich Sigma Aldrich 1,1-Dimethybiguanide hydrochloride 4 * 5 g 115-70-4 C4H11N5 H218 Fridge - Health Hazard D150959 Warning - Health Hazard
Sigma Aldrich Sigma Aldrich Bovine serum albumin 1 * 5 g 9048-46-8 N/A H218 Fridge - Health Hazard B4287 Warning - Health Hazard
AK Scientific AK Scientific 6-Bromo-2-oxindole, 95% 1 * 100 g 99365-40-9 C8H6BrNO H211 Fridge - Health Hazard J92385 Warning - Irritant
Fisher Scientific Fisher Scientific Hydrochloric Acid 38%
Muriatic acid; Hydrogen chloride; HCl
1 * 2.5 L 7647-01-0 HCl R123 Fumehood Acid Storage Danger - Corrosive and Health Hazard
Sigma Aldrich Sigma Aldrich Naphthenic Acid 1 * 1 L 1338-24-5 CnH2n-1COOH R123 Fumehood Acid Storage 70340 Warning - Health Hazard
Sigma Aldrich Sigma Aldrich Bouin's Reagent
Bouin’s fluid; Bouins solution; Bouins
1 * 1 (0.25) L 000-000-002 Mixture - see SDS for details R123 Fumehood Acid Storage HT10132 Danger - Corrosive, Health Hazard, Peroxide formation
Alfa Aesar Alfa Aesar Titanium (III) chloride 20% in 3% HCl 1 * 1 kg 7705-07-9 TiCl3 H205 Fumehood Acid Storage 39743 Danger - Corrosive Liquid
Praxair Canada Inc Praxair Canada Inc Argon Gas 99.998% 1 * 1 Q-Cyl 7440-37-1 Ar R139 Gas Storage Rack N/A Warning - Compressed Gas and Asphyxiant
Linde (Praxair) Linde (Praxair) Acetylene Compressed Gas
ACN, Acetylene Dissolved, Acetlyen, Ethyne
1 74-86-2 C2H2 R139 Gas Storage Rack Danger - Asphyxiant, Compressed Gas and Flammable Gas
Linde (Praxair) Linde (Praxair) Helium Compressed Gas
Helium-4, refridgerant gas R-704, LaserStar Helium, Medipure Helium, UltraLift Helium
2 * T Cylinder 7440-59-7 He R139 Gas Storage Rack Warning - Compressed Gas and Asphyxiant
Linde (Praxair) Linde (Praxair) Argon
Shielding Gas, Argon 40, ADDvance Argon 5.0
2 * T Cylinder 7440-37-1 Ar R139 Gas Storage Rack Warning - Compressed Gas and Asphyxiant
Linde (Praxair) Linde (Praxair) Helium Liquid
Helium, Refrigerated Liquid; Helium -4; Refrigerant GAs R-704
1 7440-59-7 He R139 Gas Storage Rack Warning - Cryogenic Burn or Injury
Linde (Praxair) Linde (Praxair) Nitrogen Compressed Gas 4 * T Cylinder 7727-37-9 N2 R139 Gas Storage Rack Warning - Compressed Gas and Asphyxiant